Choosing A Tray Sealing Vendor

When choosing a packaging equipment vendor, it is critical to look for a company that will listen to your needs and wants and understand, based on their past experience, the challenges you face. The vendor should work with you to overcome those challenges, functioning as a true solutions provider, not just a business that is trying to sell a product.

Second, make sure the tray sealer manufacturer has the flexibility to customize what they offer as a standard product. Rather than be limited by off-the-shelf offerings, you want a vendor that can source a piece of equipment that addresses your specific concerns and packaging challenges.

Lastly, the tray sealer vendor you choose should have a robust customer service and support system for assisting with determining sealing parameters. They do not necessarily need to offer design of experiment (DOE), but they should be knowledgeable enough about medical device packaging to help determine sealing parameters.

Ideally, the vendor you choose will also be able to offer installation support and training, along with field service for troubleshooting and retrofitting as your tray sealing needs change.  

How Tray Sealers Are Validated

Statistical terms used in tray sealing: CPK and standard deviation

Process capability (CPK) is a statistical measurement that describes the accuracy and repeatability of a tray sealing process. Using an archery target as a metaphor, an ideal tray sealing process is like getting a tight grouping of arrows in the bullseye. A tight clustering of arrows on the target, but not on the bullseye, shows repeatability, but not accuracy.

An occasional arrow on the bullseye shows some accuracy, but little repeatability. The best tray sealing processes are both accurate and repeatable. Historically, the medical device industry has assigned that goal a CPK value of 1.3. The medical device industry is now moving away from a minimum required CPK to a CPK of what is the maximum achievable given a package’s design.

Standard deviation is another statistical measurement that describes the amount of variation or dispersement in a set of values. It provides another way of looking at process capability (CPK). Manufacturer continually eye process improvements to be able to defend the highest possible CPK, not just what is an acceptable CPK.

 

 

 

 

Processes used for validating tray sealers: IQ, OQ, and PQ

The processes that are used for validating a tray sealer are installation qualification (IQ), operation qualification (OQ), and process qualification (PQ). The IQ process enables a user to verify that their tray sealer is installed correctly according to the vendor’s instructions. Then during the OQ process, the user can verify that the tray sealer is operating in a reliable, repeatable manner and producing the expected output.

Finally, during the PQ process,  operator actions for interfacing with the equipment are assessed. Many heat sealer vendors can offer IQ and OQ documents, or at least some level of support documentation. It is difficult for them to offer PQs because key components of the PQ are the package itself and operator functions, both of which are independent of the vendor.

Tray sealer validation is an ongoing process

In the medical device industry, tray sealers must be validated for repeatability and accuracy. The industry standard is that this validation process happens annually when the sealers are calibrated. At that time, any margin of error that has creeped into the system is corrected, so that from year to year, the output is stable. Most medical device manufacturers validate their tray sealers annually. Others calibrate their tray sealers every six months or so.

Creating and Testing a Hermetic Seal

Creating and testing a hermetic seal

The most important elements needed to create a hermetic seal between a tray and lid are temperature, time, and pressure—and for tray sealing of medical devices, those three elements must be applied consistently, with little to no variability.

To determine the optimal temperature, time, and pressure to use, manufacturers must first conduct a design of experiment (DOE) in which different temperatures, pressures, and dwell times are tried on a 3D model. Then, destructive testing is used to determine which combination of temperature, pressure, and time is best. After that, the tray sealer must also be periodically validated to ensure that it is applying those optimal parameters repeatably, with little to no variability.

Types of destructive testing for sealed trays

Destructive testing on tray sealing applications in the medical device industry is typically conducted using tensile testing, burst testing, or dye penetration testing.

These tests are used to establish that the sealed tray has reached minimum barrier system properties. For example, tensile testing applies tensile (pulling) forces to determine the minimum pounds required to break the seal. Burst testing pressurizes the package until the seal is broken and can be used to identify the weakest point on the lid, tray, or seal. Dye penetration is a qualitative test of the seal; if dye penetrates to the inside of the package, then the seal is not sufficient.

Repeatedly creating a hermetic seal

Tray sealers must be carefully designed and properly installed to meet the medical device industry’s standards for accuracy and repeatability.

For example, both the top and bottom heating elements of the sealer must be under tight control to ensure that the sealing temperature is maintained within a very narrow window. In many instances, the top heating element is maintained at the sealing temperature and the bottom part of that system is unheated; however, over many cycles, heat can build up on the bottom side. That means the bottom side must be repeatedly cooled.

Any deviation in the temperature, pressure, or time used to create the hermetic seal increases the risk of lowering accuracy and repeatability.

 

 

 

The Benefits of Sealed Trays and Upward Trends

The benefits of sealed trays compared to pouches and clamshells

Sealed trays offer benefits that pouches and clamshell packaging cannot. The major advantage is product protection. A sealed tray protects a medical device for the entirety of its shelf life—through the sterilization process, shipping and distribution, storage, and ultimately, until the product is opened under sterile conditions and used in a medical setting.

For instance, many medical devices have to be unsealed and presented in a controlled manner by scrub nurses to surgeons in the operating room. Sealed trays are much better suited for this compared to flexible pouches. With a sealed tray, the nurse can peel off the lid to expose the medical device positioned in a rigid, robust platform. In certain instances, the sealed tray is designed so that the medical device can be presented in a specific way. In other instances, once the tray is opened it becomes part of the product preparation, serving as an area for mixing chemicals before a stent is placed in an artery, for example.

Pouches and clamshell packages cannot be used in the same way. Pouches do not have the rigid structure of a tray, and clamshells cannot maintain product sterility, nor offer easy opening. The main disadvantage to tray sealing is the cost. Sealed trays usually cost more than pouches.

Why the use of tray sealing is trending upward

The use of tray sealing is trending upward for two main reasons.

First, compared to pouches, sealed trays can offer better protection over a product’s entire shelf life. Second, many manufacturers are moving to tray sealing because there is a growing perception that products packaged in trays have a higher value than those packaged in pouches. Of course, manufacturers that want to move to tray sealing will need to re-evaluate their heat sealers. Achieving a hermetic bond between the lid and the tray requires an exceptionally flat and parallel sealing platform, as well as the highly regulated and consistent application of temperature and pressure.

Types of Medical Tray Sealers and Options

Types of sealers used for tray sealing medical products

Among all the different types of available sealers, constant heat sealers are the best choice for tray sealing. Constant heat sealers heat up to a set point temperature and then are very stable at that temperature. The typical cycle time on a constant heat sealer used for tray sealing applications is two to three seconds. While impulse sealers could be used for tray sealing, they require the heating bar to rise to temperature and cool down with every cycle.

That creates an impulse cycle time of about ten seconds, which is significantly longer than the cycle times possible with a constant heat sealer.  In addition, because the thermodynamics change with every cycle on an impulsive sealer, it does not lend itself to the highly accurate and repeatable systems that are required for tray sealing medical devices. Impulse sealers are typically used for packages used in consumer markets, i.e., clamshell packaging where two plastic pieces are  bonded together to create a weld seal.

Like impulse sealers, rotary sealers and cantilever sealers are not well-suited for sealing medical trays. To achieve a hermetic seal, it is critical for the both the lid and tray to conform and make intimate contact all the way around the perimeter of the tray. That means the tray sealer used must accommodate for the inherent variability of lid and tray materials by being extremely accurate and consistent, and there must be very tight parallelism across the entire sealing platform. Since cantilever sealers move in an arc, they are not able to offer the required parallelism.

Types of configurable options for tray sealers

Tray sealers can be configured with a few different options. For example, the shuttle movement of the tool into and out of the sealer can be designed to be semi-automated. Manufacturers need to weigh various pros and cons when determining whether this type of automation is advantageous.

On the one hand, configuring a tray sealer to be semi-automated can provide greater repeatability and free the operator for other tasks, such as pre-kitting or inspection, and that could potentially increase throughput. However, for safety reasons, semi-automating a tray sealer typically creates a process that is slower than if the operator was working unassisted. That can increase cycle time and decrease output.

Tray sealers can also be configured with barcode scanning. A barcode scanner can be used to ensure that the correct recipe is loaded onto the tray sealer for the next run and to verify that the tool that is loaded is the correct one for the recipe that is currently running. Other options, such as in-line non-destructive seal inspection are currently in development.

How Sealed Trays Are Sterilized

How Sealed Trays Are Sterilized

The different types of sterilization processes used with tray sealing

Tray sealing is commonly used to package medical devices that need to be shipped and stored under sterile conditions. The sterilization process happens post-packaging, i.e., after the sealed package has exited the tray sealer. The sealed tray is sent to a sterilization facility which applies one of these sterilization processes: ethylene oxide (EtO) sterilization, electron beam (e-beam) sterilization, radiation sterilization, or steam sterilization.

sterilization is the most common process used to sterilize medical devices packaged in sealed trays; however, it does require at least some part of the packaging material to be permeable and yet able to maintain a sterile barrier. That is why medical devices packaged with Tyvek or medical paper are often sterilized using EtO. In the case of a sealed tray with a lid made of Tyvek, the EtO gas passes through the Tyvek material, killing any contaminating microorganisms that are inside the package.

Then, the pressure is relieved, as regular air is pumped back into the sterilization chamber, dispersing the EtO gas. The Tyvek fibers are bonded in a way that prevents penetration by microorganisms while allowing penetration by air molecules, which are much smaller. As a result, as long as the tray remains sealed, the contents are sterile.

Some sealed trays are sterilized using electron beam (e-beam) sterilization or radiation sterilization. These sterilization processes are ideal for sealed trays made from materials with little to no permeability like foils or plastics, or for products that are very dense. As the names imply, e-beam sterilization uses electron beams to sterilize the medical product after packaging, and radiation sterilization uses radiation, usually in the form of high energy gamma rays.

Lastly, sealed trays can also be sterilized using high temperature and pressure (i.e., steam). Products and packaging that are sterilized by steam must be able to withstand high temperatures and possibly condensation. Steam sterilization cannot be used if there is concern that process could create water vapor or droplets that affect the product packaged in the sealed tray.